Product Features
Since 2003, BWT has nearly 20 years of experience in R&D and production of fiber laser pump sources, and has a good reputation in the industry. BWT's fiber lasers also use self-developed pump sources, which further proves the stable performance and high reliability of BWT's pump sources. In the product development stage, BWT will conduct various inspections on suppliers, select high-quality raw materials, and then put them into production after ensuring high quality. Fully automated production equipment is used in the production process to ensure the performance consistency of batch products.Main Features
Wavelength:793nm Output power: 90W Fiber core diameter: 200μm Optical fiber numerical aperture:0.22 NA Feedback protection:1900nm~2100nm Applications: Fiber laser pumping Scientific research Specifications(25℃) | Symbol | Unit | K793DN1RN-90.00W | |||
Minimum | Typical | Maximum | ||||
Optical Data(1) | CW Output Power | PO | W | 90 | - | - |
Center Wavelength | lc | nm | 793±3 | |||
Spectral Width(FWHM) | △l | nm | - | 3 | 5 | |
Wavelength Shift with Temperature | △l/△T | nm/℃ | - | 0.3 | - | |
0.15/0.22NA | - | % | 85 | 90 | - | |
Electrical Data | Electrical-to-Optical Efficiency | PE | % | - | 38 | - |
Threshold Current | Ith | A | - | 11 | 12.5 | |
Operating Current | Iop | A | - | 1.6 | - | |
Operating Voltage | Vop | V | - | 21.6 | 24 | |
Slope Efficiency | η | W/A | - | 9.5 | - | |
Fiber Data | Core Diameter | Dcore | μm | - | 106.5 | - |
Cladding Diameter | Dclad | μm | - | 125 | - | |
Numeric Aperture | NA | - | - | 0.22 | - | |
Fiber Length | Lf | m | - | 2 | - | |
Fiber Loose Tubing Diameter | - | mm | 0.9 | |||
Minimum Bending Radius | - | mm | 50 | - | - | |
Fiber Termination | - | - | Ferrule | |||
Feedback Isolation | Wavelength Range | - | nm | 1900~2100 | ||
Isolation | - | dB | - | 30 | - | |
Others | ESD | Vesd | V | - | - | 500 |
Storage Temperature(2) | Tst | ℃ | -20 | - | 70 | |
Lead Soldering Temp | Tls | ℃ | - | - | 260 | |
Lead Soldering Time | t | sec | - | - | 10 | |
Operating Case Temperature(3) | Top | ℃ | 20 | - | 30 | |
Relative Humidity | RH | % | 15 | - | 75 |